Research Publications
Permanent URI for this communityhttps://dspacenew8-imu.refread.com/handle/123456789/127
Browse
4 results
Search Results
Item Effect of measurement temperature on interfacial charge freed from deep traps located at the interface of oil-paper insulation(IEEE, 2018-12-07) Dey, Debangshu; Sarkar, A.; Pal, Sayantan; Kumar, A.; Mishra, Deepak; Baral, Arijit; Haque, Nasirul; Chakravorti, SivajiAccumulation of interfacial charge creates local field distortion during insulation response measurement. Furthermore, such localized field enhancement affects the interaction between polar compounds present within oil-paper insulation and in turn affects its aging process. By getting sufficient trap energy (normally by thermal oscillation) these trapped charges dislocate from their locations and contribute in depolarization current. These interfacial charges include charges dislocated from shallow and deep sites at interfacial region. The charge residing at deep locations takes more time to dislodge themselves compared to charge residing at shallow sites. As dipole present in cellulose has large relaxation time, there might be some relation between deep charge and paper insulation sensitive parameters. In this work, effects of temperature on deep traps are analyzed. Results reported in this paper shows that magnitude of charge freed from deep locations maintains a correlation with measurement temperature and paper conductivity.Item Prediction of insulation sensitive parameters of power transformer using detrended fluctuation analysis based method(IEEE, 2022-06) Dutta, Saurabh; Dey, Jagriti; Mishra, Deepak; Baral, Arijit; Chakravorti, SivajiUtilities prefer to perform a condition-based assessment of power transformer insulation in the least possible shutdown time. It is essential to estimate the values of various insulation condition sensitive performance parameters with higher accuracy. In the present work, a technique for the estimation of performance parameters, moisture content of paper, dissipation factor of the entire oil-paper insulation, paper conductivity, and activation energy is proposed. The evaluation of these parameters using reported techniques requires complete measurement of polarization and depolarization current profile, which requires around 20000 s of measurement time. The present method uses a forecasted polarization current profile obtained from 600 s of measured polarization current data. Detrended Fluctuation Analysis is applied to the forecasted polarization current data obtained from various in-service power transformers to obtain a suitable parameter. It is shown that this parameter maintains well-defined relationships with parameters; moisture content of paper, dissipation factor of oil-paper insulation, paper conductivity, and activation energy. The proposed technique is beneficial for utilities as it eliminates the requirement of measuring depolarization current and return voltage measurement for estimating activation energy.Item Investigation related to performance parameter estimation of power transformer insulation using interfacial charge(IEEE, 2020-08-04) Mishra, Deepak; Verma, R.; Baral, Arijit; Chakravorti, SivajiIn the present paper, geometric capacitance is used as a normalization factor instead of DC insulation resistance. The results suggest geometric capacitance is more efficient in reducing geometry effect on the DC-trapped charge. The influence of normalizing deep charge using DC insulation resistance and geometric capacitance and their effect on estimating various insulation sensitive parameters are compared in this paper.Item Reduction of time domain insulation response measurement duration for fast and effective diagnosis of power transformer(IEEE, 2018-10-05) Mishra, Deepak; Pradhan, A. K.; Baral, Arijit; Chakravorti, SivajiAging sensitive parameters like dissipation factor, oil and paper conductivity and paper moisture can be estimated from insulation model parameterized using polarization current to assess the condition of transformer insulation. However, polarization current measurement is a time-consuming offline technique. During measurement, variation of environmental conditions (especially temperature) affects the monotonically decreasing nature of recorded data. Analysis of such affected data lead to incorrect conclusion regarding insulation condition. Power transformer being a crucial equipment, utility prefer to reduce its shut down time to minimum amount. In this paper a technique is discussed through which the polarization current measurement time can be reduced significantly. Several transformer data are used for verification of developed method. Presented results show that measurement data corresponding to only 10 minutes is sufficient to estimate the remaining data through the application of discussed method.