Reduction of time domain insulation response measurement duration for fast and effective diagnosis of power transformer

dc.campusKolkata
dc.contributor.authorMishra, Deepak
dc.contributor.authorPradhan, A. K.
dc.contributor.authorBaral, Arijit
dc.contributor.authorChakravorti, Sivaji
dc.date.accessioned2023-07-19T11:34:55Z
dc.date.accessioned2025-04-01T07:57:45Z
dc.date.available2023-07-19T11:34:55Z
dc.date.issued2018-10-05
dc.description.abstractAging sensitive parameters like dissipation factor, oil and paper conductivity and paper moisture can be estimated from insulation model parameterized using polarization current to assess the condition of transformer insulation. However, polarization current measurement is a time-consuming offline technique. During measurement, variation of environmental conditions (especially temperature) affects the monotonically decreasing nature of recorded data. Analysis of such affected data lead to incorrect conclusion regarding insulation condition. Power transformer being a crucial equipment, utility prefer to reduce its shut down time to minimum amount. In this paper a technique is discussed through which the polarization current measurement time can be reduced significantly. Several transformer data are used for verification of developed method. Presented results show that measurement data corresponding to only 10 minutes is sufficient to estimate the remaining data through the application of discussed method.
dc.identifier.citationD. Mishra, A. K. Pradhan, A. Baral and S. Chakravorti, "Reduction of time domain insulation response measurement duration for fast and effective diagnosis of power transformer," in IEEE Transactions on Dielectrics and Electrical Insulation, vol. 25, no. 5, pp. 1932-1940, Oct. 2018, doi: 10.1109/TDEI.2018.007322.
dc.identifier.issn1070-9878
dc.identifier.issn1558-4135
dc.identifier.urihttps://ieeexplore.ieee.org/document/8484907
dc.identifier.urihttps://dspacenew8-imu.refread.com/handle/123456789/2668
dc.language.isoen_US
dc.publisherIEEE
dc.schoolSchool of Marine Engineering and Technology
dc.subjectDielectric polarization
dc.subjectTime domain measurements
dc.subjectPower transformer insulation
dc.subjectNeural network
dc.titleReduction of time domain insulation response measurement duration for fast and effective diagnosis of power transformer