A novel methodology is suggested to predict the condition of Oil-paper Insulation (OPI), popularly used in power transformers. The proposed method is based on transient measurement of polarization current data from laboratory samples. Initially, complete polarization current profile is used to formulate an insulation model and then find the rise time of the system. After that, a relation is provided between rise time and measured performance parameters like moisture content(%pm). Further, another relation is suggested between rise time and the initial decay rate of recorded data. Hence, just by knowing the value of the initial decay rate, the value of crucial parameters like %pm can be evaluated using the proposed relationship.

Description

Keywords

Power Transformer, Dielectric Testing, Moisture, Insulation