Research Publications
Permanent URI for this communityhttps://dspacenew8-imu.refread.com/handle/123456789/127
Browse
23 results
Search Results
Item A fast and effective method for assessing insulation condition based on time domain spectroscopy data(IEEE, 2022-01-21) Mishra, Deepak; Pandey, Sandeep; Baral, ArijitA novel methodology is suggested to predict the condition of Oil-paper Insulation (OPI), popularly used in power transformers. The proposed method is based on transient measurement of polarization current data from laboratory samples. Initially, complete polarization current profile is used to formulate an insulation model and then find the rise time of the system. After that, a relation is provided between rise time and measured performance parameters like moisture content(%pm). Further, another relation is suggested between rise time and the initial decay rate of recorded data. Hence, just by knowing the value of the initial decay rate, the value of crucial parameters like %pm can be evaluated using the proposed relationship.Item A method to predict degree of polymerization value of oil-paper insulation using interfacial charge(IEEE, 2029-12-20) Singh, Vijeta; Mishra, Deepak; Baral, Arijit; Chakravorti, SivajiAnalysis based on Degree of Polymerization (DP) value is assumed to provide reliable regarding insulation condition. However, due to the invasive nature of testing, DP value based-analysis is not feasible in practical cases as it requires a paper sample from the in-service unit. Here, an attempt is made to develop a methodology to predict DP value based on non-invasive testing of oil-paper insulation. In this paper, it is found that DP value maintains a well-known relation with interfacial charge (estimated using Polarization Depolarization Current data) as both these parameters are related to the cellulosic condition. The proposed method successfully applied on various laboratory prepared samples containing different moisture content.Item Estimation of performance parameters using charge freed from deep traps located at interfacial region of oil-paper insulation(IEEE, 2019-11-21) Mishra, Deepak; Verma, R.; Baral, Arijit; Haque, Nasirul; Chakravorti, SivajiDe-trapped charge dislodged from interfacial region of oil-paper insulation can be used as an effective insulation sensitive parameter. Over time, various physiochemical reactions takes place at interfacial region and consequently results in the formation of different trap sites (deep and shallow). Charges which resides at these traps sites are de- trapped after gaining sufficient energy. In present analysis, it is found that charge dislocated from deep traps maintains some specific type of relationship with different insulation sensitive parameters. Before using de-trapped (dislodge from deep traps) as an effective insulation sensitive parameter the effect of geometry must be reduced, as amount of de-trapped charge depends on the area of interfacial region which is not identical for all units. Result presented in this paper shows that use of geometric capacitance for normalization purposes significantly reduces the effects of insulation physical dimensions on de- trapped charge. The capability of deep charge (normalized using dc insulation resistance and geometrical capacitance) is also compared in the present work.Item Effect of measurement temperature of insulation poles used for assessment of oil-paper insulation(IEEE, 2018-12-07) Verma, R.; Mishra, Deepak; Baral, Arijit; Chakravorti, SivajiAnalysis of Polarization-depolarization current (PDC) data is a popular technique used for assessing condition of oil-paper insulation. Oil-paper insulation deteriorates with aging during the operational life of the power equipment. In order to get information regarding the insulation condition; different performance parameters are used which can be estimated from PDC data. These parameters include paper moisture (%pm), Dissipation factor (%tanδ) and paper conductivity (σ paper ). In addition to these parameters, insulation poles can also be used for insulation diagnosis. Recently, it has gained popularity in field of insulation diagnosis as it does not depend on physical geometry of insulation. In this paper, the effect of measurement temperature on insulation poles has been analysed. Also, an attempt has been made to establish a relation between insulation poles and other insulation sensitive parameters such as %pm, σ paper and %tan δ.Item Effect of measurement temperature on interfacial charge freed from deep traps located at the interface of oil-paper insulation(IEEE, 2018-12-07) Dey, Debangshu; Sarkar, A.; Pal, Sayantan; Kumar, A.; Mishra, Deepak; Baral, Arijit; Haque, Nasirul; Chakravorti, SivajiAccumulation of interfacial charge creates local field distortion during insulation response measurement. Furthermore, such localized field enhancement affects the interaction between polar compounds present within oil-paper insulation and in turn affects its aging process. By getting sufficient trap energy (normally by thermal oscillation) these trapped charges dislocate from their locations and contribute in depolarization current. These interfacial charges include charges dislocated from shallow and deep sites at interfacial region. The charge residing at deep locations takes more time to dislodge themselves compared to charge residing at shallow sites. As dipole present in cellulose has large relaxation time, there might be some relation between deep charge and paper insulation sensitive parameters. In this work, effects of temperature on deep traps are analyzed. Results reported in this paper shows that magnitude of charge freed from deep locations maintains a correlation with measurement temperature and paper conductivity.Item Feasibility of using normalized de-trapped charge for diagnosis of power transformer insulation(IEEE, 2018-10-07) Mishra, Deepak; Baral, Arijit; Haque, Nasirul; Chakravorti, SivajiIn order to use de-trapped interfacial charge as a performance parameter for diagnosis, it is necessary to reduce the influence of insulation geometry. Available literature shows that this can be done by considering dc insulation resistance R 0 as the normalization factor. Such normalization may not be always practically feasible as information regarding R 0 requires measurement of temperature sensitive low amplitude current. In this paper it is shown that geometric capacitance C 0 (instead of R 0 ) can be used as an effective normalization parameter to reduce effect of insulation geometry. Effect of normalizing freed interfacial charge using C 0 and R 0 and its subsequent effect on insulation diagnosis are presented in this paper.Item Effect of interfacial charge on parameters considered for insulation diagnosis of power transformer(IEEE, 2017-12-02) Mishra, Deepak; Baral, Arijit; Pradhan, Arpan Kumar; Haque, Nasirul; Chakravorti, SivajiOut of various analysis methods available Polarization Depolarization Current (PDC) measurement is extensively used for monitoring of oil-paper insulation health. In such case, Classical Debye Model (CDM) is used for analysis of recorded PDC data. CDM has limited capacity to simulate the effect of interfacial charge. Due to this interfacial charge, nonlinearity arises in the system which adversely affects the insulation. Conductivity difference between oil and paper is the main reason behind this interfacial charge which creates nonlinearity in system. In the present work, the effect of interfacial charge is analyzed on some of the performance parameters used for diagnosis of insulation like peak value of return voltage spectrum and paper conductivity.Item Effect of charge accumulated at oil-paper interface on zero of transfer function formulated using classical debye model parameters(IEEE, 2017-11) Mishra, Deepak; Pradhan, Arpan Kumar; Baral, Arijit; Haque, Nasirul; Chakravorti, SivajiPDC measurement and analysis is one of widely used tool for reliable diagnosis of power transformer insulation. In different reported methods of analysis it is considered that polarization current is composed of the current due to dipole movement and conduction current. Similarly the depolarization current is assumed to be composed of relaxation of dipoles. However when the dc conduction effect is removed from polarization current it is found the resulting current is not similar to the measured depolarization current. This deviation in both the currents show the presence of nonlinearity in the system. This nonlinearity arises due to migration of trapped charges that reside at the interfacial region of oil-paper insulation. The present paper shows the effect of such free charge on some important performance parameters like paper moisture and zero of Transfer Function of Classical Debye Model.Item Importance of depolarization current in the diagnosis of oil-paper insulation of power transformer(IEEE, 2023-06-07) Kumar, Alok; Mishra, Deepak; Baral, ArijitRecently, Polarization Depolarization current (PDC) measurement is widely accepted time domain spectroscopy-based method for assessing the insulation condition. Various performance parameters like Dissipation factor (%tan δ ), Paper Moisture (%pm), Dielectric Adsorption Ratio (DAR), Polarization index (PI) etc. can be estimated by analyzing the PDC data. During field measurement various factors influences the recorded PDC data. As per existing literature, presence of low frequency noise, effect of temperature variation and influence of residual charge are common during field measurement. These factors significantly affect recorded polarization current and hence estimated performance parameters. Hence, analysis using recorded polarization current data may provide misleading information regarding insulation condition. Under such practical situation where polarization current is affected by above mentioned factors that generally observed during field measurement, depolarization current should be used for analysis of insulation condition. The depolarization current does not influence by such external factors. The present work shows the importance of depolarization current where polarization current is influenced by external low frequency noise and residual charge. The analysis firstly applied on sample prepared in the laboratory and then on data collected from real life in-situ transformers. The results obtained from the analysis shows that the data obtained from depolarization current is more reliable.Item A novel method to predict severity of thermal aging and degree of polymerization for reliable diagnosis of dry-type insulation(IEEE, 2022-04) Mishra, Shalini; Baral, Arijit; Mishra, Deepak; Chakravorti, SivajiThe effect of thermal aging on Nomex-paper-based vacuum pressure impregnation (VPI) insulation is reported in this article. The frequency-dependent dielectric loss of Nomex-paper-based VPI dry insulation is affected after significant thermal aging. This variation in dielectric loss of the insulation maintains a good correlation with the duration of thermal aging. A new parameter sensitive to the severity of thermal aging is also introduced. To identify the parameter, the excitation voltage waveform and the corresponding insulation response at a given frequency are required. Determining the parameter does not require denoising of recorded waveforms, reducing the overall computational burden. Based on the newly introduced parameter, a cost-effective method is proposed to predict the dielectric loss and degree of polymerization (DP) in a thermally aged VPI-type dry insulation. The proposed method employs the intermediate frequency range and hence does not require time-consuming low-frequency measurements.
- «
- 1 (current)
- 2
- 3
- »