Feasibility of using normalized de-trapped charge for diagnosis of power transformer insulation

No Thumbnail Available

Date

2018-10-07

Journal Title

Journal ISSN

Volume Title

Publisher

IEEE

Abstract

In order to use de-trapped interfacial charge as a performance parameter for diagnosis, it is necessary to reduce the influence of insulation geometry. Available literature shows that this can be done by considering dc insulation resistance R 0 as the normalization factor. Such normalization may not be always practically feasible as information regarding R 0 requires measurement of temperature sensitive low amplitude current. In this paper it is shown that geometric capacitance C 0 (instead of R 0 ) can be used as an effective normalization parameter to reduce effect of insulation geometry. Effect of normalizing freed interfacial charge using C 0 and R 0 and its subsequent effect on insulation diagnosis are presented in this paper.

Description

Keywords

Space charge, Dielectric measurement, Power transformer, Dielectric materials

Citation

D. Mishra, A. Baral, N. Haque and S. Chakravorti, "Feasibility of using Normalized De-trapped Charge for Diagnosis of Power Transformer Insulation," 2018 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC), Kota Kinabalu, Malaysia, 2018, pp. 555-558, doi: 10.1109/APPEEC.2018.8566434.

Endorsement

Review

Supplemented By

Referenced By