Effect of charge accumulated at oil–paper interface on parameters considered for power transformer insulation diagnosis

dc.campusKolkata
dc.contributor.authorMishra, Deepak
dc.contributor.authorHaque, Nasirul
dc.contributor.authorBaral, Arijit
dc.contributor.authorChakravorti, Sivaji
dc.date.accessioned2023-07-20T04:46:53Z
dc.date.accessioned2025-04-01T07:57:45Z
dc.date.available2023-07-20T04:46:53Z
dc.date.issued2018-01-02
dc.descriptionErrata An Erratum has been published for this content: Corrigendum: Effect of charge accumulated at oil–paper interface on parameters considered for power transformer insulation diagnosis
dc.description.abstractPolarisation and depolarisation current (PDC) measurement and analysis is one of the popular tools for effective diagnosis of power transformer insulation. Normally, it is assumed that polarisation current is the combination of the current due to dipole movement and conduction current. Similarly, the depolarisation current is only due to the relaxation of dipoles. However, it is found that after eliminating the effect of dc conduction from polarisation current the resulting current is not similar to that of measured depolarisation current. This shows some non-linearity is present in the system. This non-linearity occurs due to movement of trapped charge that resides in the interfacial region of oil–paper insulation. This study shows the effect of de-trapping charge on various performance parameters that are used for insulation diagnosis like paper moisture and dielectric dissipation factor (tanδ).
dc.identifier.citationD. Mishra, N. Haque, A. Baral, and S. Chakravorti, “Effect of Charge Accumulated at Oil-Paper Interface on Parameters Considered for Power Transformer Insulation Diagnosis”, IET Science, Measurement and Technology, Vol. 12, No. 3, pp.411 – 417, 2018. DOI: 10.1049/iet-smt.2017.0354
dc.identifier.issn1751-8822
dc.identifier.urihttps://dspacenew8-imu.refread.com/handle/123456789/2667
dc.language.isoen_US
dc.publisherThe Institution of Engineering and Technology
dc.schoolSchool of Marine Engineering and Technology
dc.subjectCurrent measurement
dc.subjectDielectric materials and properties
dc.subjectTransformers and reactors
dc.titleEffect of charge accumulated at oil–paper interface on parameters considered for power transformer insulation diagnosis
dc.typeArticle

Files

Original bundle

Now showing 1 - 2 of 2
No Thumbnail Available
Name:
IET Science Measure Tech - 2018 - Mishra - Effect of charge accumulated at oil paper interface on parameters considered.pdf
Size:
2.06 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Corrigendum.pdf
Size:
222.54 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description:

Collections